• Iodixanol 320 Results in Better Renal Tolerance and Radiodensity than Do Gadolinium-based Contrast Media: Arteriography in Ischemic Porcine Kidneys

    Barbara Elmståhl, MD, PhD Ulf Nyman, MD, PhD Peter Leander, MD, PhD Klaes Golman, PhD Chun-Ming Chai, MD, PhD Derek Grant, PhD Richard Doughty, PhD Rikard Pehrson, PhD Jonas Björk, PhD Torsten Almén, MD, PhD

    Purpose: To prospectively compare nephrotoxicity and radiodensity of plasma hyperosmotic gadolinium chelates (attenuation-osmotic ratio of 1:1) with those of plasma iso-osmotic iodine-based contrast media (attenuation-osmotic ratio of 3:1 or 6:1) after renal arteriography in ischemic porcine kidneys.

    Materials and Methods: The local animal care committee approved this study. The following contrast media were used: (a) iodixanol (150 mg of iodine per milliliter and 320 mg I/mL, 0.29 osm/kg H2O), (b) iopromide (150 mg I/mL, 0.34 osm/kg), (c) 0.5 mol/L ga-dodiamide (0.78 osm/kg), and (d) 1.0 mol/L gadobutrol (1.6 osm/kg). After left-sided nephrectomy, contrast media (3 mL per kilogram of body weight) were injected (20 mL/min) in a noncrossover design into the right renal artery of pigs during a 10-minute ischemic period. There were eight pigs in each group and one group for each contrast medium. We compared histo-morphology, radiographic contrast medium excretion, subjective radiodensity of nephrograms (70 kVp) at the end of injection, and contrast medium plasma half-life elimination times 1-3 hours after injection. Longer elimination times resulted in lower glomerular filtration rates.

    Results: Gadobutrol caused extensive tubular necrosis and moderate glomerular necrosis; gadodiamide and iopromide, minimal to mild tubular necrosis; and iodixanol, no necrosis. Gadobutrol was the only contrast medium to show no sign of excretion, and its plasma half-life elimination time (median, 1103 minutes; P< .001) was significantly longer than that of other contrast agents. Gadodiamide had a significantly longer plasma half-life elimination time (median, 209 minutes; P = .01) than did iodine-based contrast media (median, 136-142 minutes). The 320 mg I/mL dose of iodixanol had the highest radiodensity, whereas gadodiamide had the lowest radiodensity. The radiodensity of the 320 mg I/mL dose of iodixanol was greater than that of the 150 mg I/mL dose of iodixanol, which was equal to the radiodensi-ties of the 150 mg I/mL dose of iopromide and 1.0 mol/L gadobutrol, which in turn were greater than that of 0.5 mol/L gadodiamide.

    Conclusion: Plasma iso-osmotic iodine-based contrast media used at commercially available concentrations have superior attenuation and nephrotoxic profiles compared with equal volumes of hyperosmotic nonionic 0.5-1.0 mol/L gadolinium-based contrast media when performing renal arteriographic procedures.