Acquisition Phase | Phase Included | Scan Delay | Respiration Phase | Anatomical Coverage |
Non Contrast | N/A | N/A | N/A | N/A |
Arterial Phase | N/A | N/A | N/A | N/A |
Venous Phase | Yes | Patient dependent | Inspiration | Region of interest |
Delayed Phase | N/A | N/A | N/A | N/A |
Scan Comments: All scans are performed using the ALARA principle. | ||||
Technical Parameters | Parameters |
kVp | Care kV (ref. kV 120) |
Effective mAs | CareDose |
Care Dose Reference mAs | 125 |
Time (Rotation) | 1.0 sec |
Average Acquisition Time | 3-5 sec |
Collimation | 128 x 0.6mm |
Pitch Value | 0.8 |
Scan Direction | Craniocaudal |
Comments: CareDose is used to limit patient exposure. | |
Reconstruction Parameters | Soft Tissue | Thin Data | Bone |
Slice Thickness | 3mm | 1.0mm | 3mm |
Reconstruction Spacing | 3mm | 0.6mm | 3mm |
Reconstruction Algorithm | I30s | I30s | I70h |
Window Width and Level | 350/50 | 350/50 | 2500/500 |
Reconstruction Comments: Coronal and sagittal soft tissue image reconstructions are also performed. | |||
Contrast Parameters | Parameters |
Contrast Type | Non ionic |
Contrast Volume | Weight based |
Saline Flush | N/A |
Injection Rate | 1.5-3ml/sec |
Oral Contrast | N/A |
Contrast Volume | N/A |
Comments: The scan delay is determined both in part by patient age, IV access, and injection rate. | |