Specific Anatomic Region | Shoulder |
Application | Trauma to shoulder joint (includes scapula and humerus) |
Author | Fishman EK |
Reference Source | Personal communication |
Scanner Used | Siemens Somatom Plus 4 |
Injection Rate | N/A |
Contrast Volume and Type | N/A |
Area Scanned | From just above acromioclavicular joint through scapular tip |
Scan Delay | None |
Length of Spiral (time) | 40sec |
Slice Thickness | 3mm |
Table Speed/Pitch | 3-5mm/sec |
Reconstruction Interval | 2mm |
3D Technique Used | Volume rendering and multiplanar obliques |
Comment: The technique can be modified if only the humeral head is injured. In cases with complex trauma IV contrast may be used to exclude a vascular injury to the mediastinum. The protocol used would use 120ml of contrast injected at 2-3ml/sec with a 30sec delay. |