Specific Anatomic Region | Esophagus | |
Application | Stage Esophageal Cancer | |
Author | Horton HM, Fishman EK | |
Reference Source | Spiral CT of the Esophagus and Stomach (in: Spiral CT: Principles, Techniques and Clinical Applications. Fishman, Jeffrey, eds. 1998) | |
Scanner Used | Siemens Somatom Plus-4 | |
Injection Rate | 2-3 cc/sec | |
Contrast Volume and Type | 120 cc of Omnipaque-350 | |
Area Scanned | From supraclavicular zone thru liver | |
Scan Delay | 40 seconds | |
Length of Spiral (time) | 35-40 sec | |
Slice Thickness | 5mm | |
Table Speed/Pitch | 8mm/sec or 1.6 pitch | |
Reconstruction Interval | 5mm | |
3D Technique Used | None needed | |
Comment: 1. EsophaCat is useful for opacification of the esophagus. 2. Key areas of difficulty are the EG jxn and the celiac axis. |