Specific Anatomic Region | Trachea | |
Application | Virtual bronchoscopy | |
Author | Lee KS et al. | |
Reference Source | RadioGraphics 1977; 17:555-567 | |
Scanner Used | GE HiSpeed Advantage | |
Injection Rate | N/A | |
Contrast Volume and Type | None | |
Area Scanned | Depends on clinical question (i.e. bronchi vs airway) | |
Scan Delay | None | |
Length of Spiral (time) | Up to 30sec | |
Slice Thickness | 3mm | |
Table Speed/Pitch | 3mm/sec | |
Reconstruction Interval | 1.5mm | |
3D Technique Used | Shaded surface | |
Comment: This technique will have a limited scan distance of 9cm. We believe you can increase the pitch to 2 which gives you 18cm coverage, which is enough for the trachea and major airways. Newer single detector scanners can cover a larger volume and the enrite airway scanned. |