64 Slice MDCT Protocols: Chest |
||
|
Specific Anatomic Region |
Aorta (thoracic) |
|
|
Application |
Trauma | |
|
Author |
Elliot K. Fishman, MD |
|
|
Reference Source |
JHU Protocol |
|
|
Scanner Used |
Siemens Sensation 64 |
|
|
KV/Effective mAs/Rotation time (sec) |
120/250/0.33 |
|
|
Detector Collimation (mm) |
0.6 |
|
|
Slice Thickness (mm) |
5 and .75 |
|
|
Pitch |
0.7 |
|
|
Kernel |
30 |
|
|
Reconstruction Interval |
5 and .5 |
|
|
Image Order (acquisition) |
Cr-ca |
|
|
Oral Contrast |
N/A |
|
|
IV contrast volume and type |
100-120 cc of Omnipaque-350 | |
|
Injection Rate |
3-4 cc/sec |
|
|
Scan delay (sec) |
20-25 sec | |
|
3D technique used |
VRT |
|
|
Comment:We prefer to gate these studies and use either bolus tracking or a test bolus technique. Gating is ideal for the aortic root. A saline chaser is helpful for the arch to eliminate artifact off the SVC. |
||