64 Slice MDCT Protocols: Abdomen

Specific anatomic region

Adrenal

Application

Evaluate incidentaloma

Author

Elliot K Fishman, MD

Reference Source

JHU Protocol

Scanner Used

Siemens Sensation 64

KV/Effective mAs/ Rotation time (sec)

120 / 250/ 0.5

Detector Collimation (mm)

0.6

Slice thickness (mm)

1- 3mm

Pitch

0.75

Kernel

30

Reconstruction interval

1-3mm

Image order (acquisition)

Cr-ca

Oral contrast

1000 cc water

IV contrast volume and type

Non contrast first and then IV if needed (see below)

Injection rate

3-cc/sec (if used)

Scan delay (sec)

For contrast 30 sec- 15 minutes

3D technique used

Not routinely needed

Comment:

1. Do a noncontrast CT first and if attenuation under 10Hu and it is 4 cm or less it is an adenoma and you can stop.

2. If above 20Hu you can inject 100 cc of contrast and look at the washout value (check Hu at 1 minute and then at 5 thru 15 minutes to look for a 50% washout value).