LiverEvaluate hepatic a. anatomy for liv. transplant |
|
Specific Anatomic Region |
Liver |
|
|
Application |
Evaluate hepatic arterial anatomy for liver transplant |
|
|
Author |
Winter TC III et al. |
|
|
Reference Source |
Radiology 1995; 195:363-370 |
|
|
Scanner Used |
GE HiSpeed Advantage |
|
|
Injection Rate |
5ml/sec |
|
|
Contrast Volume and Type |
180ml of Omnipaque 300 |
|
|
Area Scanned |
Top to bottom of liver |
|
|
Scan Delay |
12sec (approx) |
|
|
Length of Spiral (time) |
30-35sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
3-5mm/sec with a pitch of 1:1 to 1:7:1 |
|
|
Reconstruction Interval |
1mm |
|
|
3D Technique Used |
MIP and shaded-surface display |
|
|
Comment: A test bolus of 20ml is injected at 5ml/sec. A single scan is chosen just above the celiac axis. After an 8sec delay, 14 one-second scans are obtained with a one-second interscan delay. In these patients we prefer a dual-phase Spiral CT. |
||