Protocols- Head and Neck

Carotid Artery Stenosis I


Specific Anatomic Region Carotid Arteries
Application Carotid artery stenosis
Author Kuszyk, B.S.,Beauchamp, N.J.J., and Fishman, E.K. (1998).
Reference Source Neurovascular applications of CT angiography. Semin US CT MR, 19(5), 394-404.
Scanner Used Siemens Ultra CT MR
Injection Rate 3cc/sec
Contrast Volume and Type 120cc of Omnipaque 350
Area Scanned From C4 to base of skull
Scan Delay 18sec
Length of Spiral (time) 25-30sec
Slice Thickness 2mm
Table Speed/Pitch 4mm/sec or a pitch of 2
Reconstruction Interval 1mm
3D Technique Used Volume rendering with MIP as a supplement
Comment: The key is to edit out obscuring structures in order to define the carotid aa without overlapping structures which may interfere with accuracy.